Goodman Air Conditioner and Furnace Repair
Experiencing issues with your Goodman AC or Furnace? Looking for professional service or installation of a new Goodman system? Look no further than North Wind’s exceptional team of technicians. Our dedicated experts are ready to assist you with all your HVAC needs.



Goodman HVAC Experts
Goodman is a highly reputable company, trusted by homeowners and professionals for decades. They offer reliable, energy-efficient, and cutting-edge heating, ventilation, and air conditioning products. As a leading brand, Goodman sets the standard for quality and performance, making them the top choice for customers seeking professional HVAC solutions.
At North Wind, we specialize in expert repair, installation, and maintenance services for Goodman HVAC systems, providing absolute peace of mind to our customers.
- Free Estimate
- Same-Day Service (24/7)
Are You Looking For
Goodman Furnace and AC Repair Near Me
For dependable Goodman furnace and AC repair, North Wind is your trusted HVAC service provider. Our skilled technicians specialize in handling all issues related to Goodman systems, offering on-site repairs or comprehensive repair plans.
Whether it’s a minor fix or a complete overhaul, we deliver prompt and efficient solutions to keep your home comfortable year-round. With North Wind, your Goodman equipment is in capable hands, providing you with peace of mind and a comfortable living environment.
Expert Technicians
With Years of ExperienceFast and Reliable
Available 24/7Affordable Services
Quality Service, Unbeatable PriceCertified and Qualified
Fully Licensed, TSSA ApprovedNorth Wind HVAC
Goodman Repair & Installation Services
What We Do:
Goodman HVAC Services
Goodman Furnace Repair & Installation
When it comes to Goodman furnace repair and installation, North Wind is the name you can rely on. Our certified technicians have extensive experience in dealing with Goodman furnaces and can quickly diagnose and resolve any issues they may encounter. Whether your furnace is experiencing a malfunction or you’re looking to install a new Goodman unit, we have the expertise to ensure your furnace operates at its best.
Why is my Goodman furnace not turning on at all?
Several reasons could cause this issue. First, check if the thermostat is set to “heat” and the desired temperature is higher than the room temperature. Ensure that the circuit breaker or fuse for the furnace is not tripped or blown. If these are not the problem, it could be an issue with the ignition system, gas supply, or a faulty thermostat. In such cases, it’s best to call a professional technician for diagnosis and repair.
Why is my Goodman furnace constantly running without reaching the set temperature?
This could be due to a dirty or clogged air filter, restricting airflow and causing the furnace to work harder. Check the air filter and replace it if necessary. If the issue persists, the thermostat calibration might be off, or there could be a problem with the furnace’s blower motor or heat exchanger. Consulting a qualified technician is recommended for a thorough assessment.
My Goodman furnace is making unusual noises during operation. What could be the cause?
Unusual noises can indicate various issues, such as rattling due to loose components, banging caused by a faulty ignition or delayed ignition, or squealing due to a worn-out blower belt. Grinding noises might signal an issue with the blower motor or other internal parts. It’s crucial to have a technician inspect and diagnose the source of the noise to prevent further damage.
How often should I schedule maintenance for my Goodman furnace?
It’s advisable to schedule annual maintenance for your Goodman furnace. Regular maintenance ensures that the system operates efficiently, minimizes the risk of breakdowns, and extends the lifespan of the equipment. Spring or fall is an ideal time to have your furnace serviced.
How can I improve the energy efficiency of my Goodman furnace?
To enhance energy efficiency, ensure that the air filter is clean and regularly replaced. Seal any air leaks in the ductwork or around the furnace. Consider installing a programmable thermostat to regulate temperature settings efficiently. Additionally, scheduling annual professional maintenance will optimize the furnace’s performance.
Goodman AC Repair & Installation
If your Goodman air conditioning system is acting up, don’t sweat it – North Wind is here to help. Our skilled technicians are well-versed in Goodman AC repair and installation, proficiently handling various AC problems to restore cool comfort to your home. From minor repairs to complete system installations, we’ve got you covered.
Why is my Goodman AC not cooling the room effectively?
Inadequate cooling can be caused by a dirty air filter, obstructed condenser unit, refrigerant leaks, or a malfunctioning compressor. Check the air filter and clean or replace it as needed. Ensure that the outdoor unit is free from debris and vegetation. If the issue persists, it’s best to have a professional technician inspect and diagnose the problem.
My Goodman AC is blowing warm air. What could be the issue?
Several factors could cause this problem. It could be due to low refrigerant levels, a faulty compressor, a frozen evaporator coil, or a malfunctioning thermostat. Turn off the AC and let the frozen coil thaw before attempting to restart it. If the issue persists, contact a licensed HVAC technician to identify and resolve the root cause.
How often should I change the air filter in my Goodman AC?
For optimal performance and energy efficiency, it’s recommended to change the air filter every 1 to 3 months, depending on factors like the indoor air quality, the number of occupants, and the presence of pets.
Can I install a new Goodman AC myself?
Installing a new AC unit requires specialized knowledge and skills. It involves electrical work, refrigerant handling, and proper equipment setup. To ensure safety and proper functioning, it’s best to have a professional HVAC technician handle the installation.
Why is my Goodman AC making strange noises during operation?
Unusual sounds may indicate loose parts, a damaged fan blade, or problems with the motor or compressor. Turn off the AC and avoid using it until a qualified technician can inspect and repair the unit to prevent further damage.
We Are Here For You
This is Why You Should Call Us
Choosing North Wind for your HVAC needs is a decision you’ll be glad you made. Our dedication to customer satisfaction sets us apart, and our skilled technicians provide exceptional service. Whether it’s repair, installation, or maintenance of your HVAC system, we bring expertise and efficiency to every job.
With years of experience, we understand HVAC complexities and tailor solutions to your requirements. You can expect professionalism, transparency, and top-notch results when you trust North Wind for your HVAC needs. Call us today to schedule an appointment with one of our licensed technicians.

Goodman Furnace Error Codes
1 Flash: System lockout
This means that your furnace has locked out due to too many ignition attempts. After one hour of lockout, your furnace will automatically reset itself.
2 Flashes: Pressure switch stuck closed
This means that the draft blower isn’t functioning properly, or your furnace has a short in the pressure switch circuit. You should either repair the short or replace the pressure switch.
3 Flashes: Pressure switch stuck open
This means your furnace has an open pressure switch circuit or the induced draft blower is operating when it shouldn’t be. You should check the pressure switch hose for blocks or an improper connection. Otherwise, see if any loose wiring needs tightening.
4 Flashes: Open high limit
This means your furnace has a primary open limit circuit. You should check and clean all the filters, tighten the wiring, and see if there are any blockages in the flue.
5 Flashes: Flame sense without gas valve
This means that your furnace senses a flame without a call for heat. You should check for a leaky or open gas valve or a lingering burner flame.
6 Flashes: Open rolloutor open fuse
Replace Fuse.
7 Flashes: Low flame signal
This warns of a low flame sense microamp signal. This is the result of a coated flame sensor or a lazy flame due to poor gas pressure. Adjust the gas pressure according to the information available to you.
8 Flashes: Igniter circuit problem
This means your furnace has an igniter circuit problem due to a defective igniter or an improperly connected igniter. Replace the igniter or check the ground wiring for defects.
9 Flashes: High-stage pressure switch
This means that your furnace has a high-stage pressure switch that won’t close during a high-stage-induced draft blower operation. Check your Goodman furnace for a pinched or blocked pressure switch hose.
Continuous flashes: Reversed 115 vac polarity
This means that your furnace has a reversed polarity of 115 volts. You will have to correct the wiring polarity after reviewing the wiring diagram.
Goodman AC Error Codes
CODE: A2
Shorted sensor/ Open sensor / Sensor disconnected / Sensor out of range
CODE: A3
Shorted sensor / Open sensor / Sensor disconnected / Sensor out of range
CODE: E5
Short in low voltage wiring
CODE: EE
Compressor relay contacts welded
CODE: B0
Indoor blower motor problem / Communications error between indoor and outdoor unit
CODE: B9
Indoor blower motor problem / Blocked filters / Restrictive or undersized ductwork / Indoor-outdoor unit miss match
CODE: D0
Air conditioner is wired as part of a communicating system and integrated control module does not contain any shared data
CODE: D1
Air conditioner is wired as part of a communicating system and integrated control module contains invalid shared data or network data is invalid for the integrated control module
CODE: D2
Air conditioner/heat pump is wired as part of a communicating system and outdoor unit requires airflow greater than indoor unit’s airflow capability / Shared data is incompatible with the system or missing parameters
CODE: D3
Shared data sent to integrated control module does not match hardware configuration
CODE: D4
Shared data on memory card has been rejected
CODE: 01
Low refrigerant charge / Restriction in liquid line / Indoor blower motor failure / Indoor thermostat set extremely low
CODE: 02
Blocked condenser coil / Outdoor fan not running
CODE: 03
Intermittent thermostat demand / Faulty compressor relay
CODE: 04
Compressor bearings are seized / Failed compressor run capacitor / Faulty run capacitor wiring / Faulty compressor wiring./Low line voltage
CODE: 05
Power is disconnected / Failed compressor protector / Compressor not properly wired to control
CODE: 06
Compressor start winding is open / Failed compressor run capacitor / Faulty run capacitor wiring / Compressor not properly wired to control / Faulty compressor wiring
CODE: 07
Compressor run winding is open / Compressor no properly wired to control / Faulty compressor wiring
CODE: 08
Low line voltage / High line voltage
CODE: 09
Control detects secondary voltage less than 18 VAC / Transformer overloaded / Low line voltage
Please note that these error codes are general and may not cover every possible variation. Always refer to your Goodman furnace and AC manual or consult a professional technician for accurate diagnosis and resolution.