WE ARE HIRING NOW
Proudly Canadian
$25 OFF FURNACE REPAIR & $120 MAINTENANCE
North Wind HVAC proudly provides exceptional Amana HVAC services, ensuring precise heating and cooling solutions tailored to your home’s needs. Count on North Wind HVAC for all your Amana furnace and AC repairs and installations, as we are committed to delivering reliable and efficient solutions to keep your home comfortable year-round.
At North Wind HVAC, we specialize in offering premium Amana HVAC services to ensure optimal comfort in your home. With Amana’s reputation for superior quality and innovation in the HVAC industry, you can trust us to deliver top-notch solutions tailored to your specific heating and cooling needs. Whether you require Amana furnace repairs, AC installations, or maintenance services, our skilled technicians are dedicated to providing reliable and efficient solutions that exceed your expectations.
At North Wind HVAC, our commitment to excellence shines through in every Amana HVAC service we provide. From prompt and professional repairs to expert installations, we prioritize customer satisfaction above all else. With our comprehensive knowledge of Amana systems and our dedication to delivering personalized solutions, you can rest assured that your home’s comfort is in good hands with North Wind HVAC. Trust us to keep you cozy and cool with our dependable Amana HVAC services.
Are You Looking For
When you’re in need of Amana furnace and AC repair services nearby, look no further than North Wind HVAC. Our expert technicians specialize in diagnosing and fixing issues with Amana heating and cooling systems promptly and efficiently. With our commitment to excellence and customer satisfaction, you can trust us to provide reliable repairs that restore comfort to your home quickly.
At North Wind HVAC, we understand the urgency of having a properly functioning furnace and air conditioner, especially during extreme weather conditions. That’s why we offer fast and reliable Amana furnace and AC repair services right in your neighborhood. Whether it’s a minor issue or a major malfunction, our team is dedicated to delivering high-quality repairs that ensure your Amana system operates smoothly and efficiently, keeping your home comfortable year-round.
North Wind HVAC
What We Do:
Trust our expert technicians to provide reliable repair and installation services for your Amana furnace. Whether it’s a minor repair or a complete installation, we ensure that your furnace operates at peak efficiency, keeping your home warm and comfortable throughout the winter months.
Signs of a malfunctioning Amana furnace include strange noises, uneven heating, increased energy bills, and frequent cycling on and off. If you notice any of these signs, it’s best to schedule a professional inspection.
Repairing your Amana furnace can be a cost-effective solution, especially if the issue is minor. Additionally, repairing allows you to extend the lifespan of your furnace and maintain its efficiency.
It’s recommended to schedule annual maintenance for your Amana furnace to ensure optimal performance and prevent potential breakdowns. Regular maintenance helps identify and address issues before they escalate.
Yes, installing a new, energy-efficient Amana furnace can help lower your energy bills by reducing energy consumption and improving heating efficiency.
Amana furnace installation requires technical expertise and knowledge of HVAC systems. It’s highly recommended to hire a professional HVAC technician for proper installation to ensure safety and performance.
When your Amana air conditioning system needs repair or installation, our skilled technicians are here to help. We specialize in servicing Amana AC units, ensuring optimal cooling performance to keep your home or business comfortable during the hottest days of summer.
Signs that your Amana AC unit may need repair include insufficient cooling, unusual noises, frequent cycling on and off, and leaks around the unit. If you notice any of these signs, it’s best to schedule a professional inspection.
The installation time for a new Amana AC unit can vary depending on factors such as the complexity of the installation, existing ductwork, and any additional components required. On average, installation can take anywhere from a few hours to a full day.
Yes, installing a new, energy-efficient Amana AC unit can help lower your energy bills by reducing energy consumption and improving cooling efficiency.
Amana AC unit installation requires technical expertise and knowledge of HVAC systems. It’s highly recommended to hire a professional HVAC technician for proper installation to ensure safety and performance.
Regular maintenance, such as cleaning or replacing air filters, keeping the outdoor unit free from debris, and scheduling annual tune-ups, can help prolong the lifespan of your Amana AC unit.
We Are Here For You
At Amana HVAC Services by North Wind, we prioritize customer satisfaction above all else. With our team of highly trained technicians, we offer prompt and professional service, ensuring that your HVAC system operates at peak performance. Whether you need repair, installation, or maintenance services, you can trust us to deliver reliable solutions tailored to your specific needs. Additionally, we are committed to using quality parts and equipment to ensure the longevity and efficiency of your Amana HVAC system. With our dedication to excellence and customer-focused approach, choosing our services guarantees peace of mind and comfort for your home or business.
Contact North Wind HVAC today to experience exceptional service and uncover our steadfast dedication to your comfort.
No signal from the thermostat. Turn off the unit’s power and check connections.
Furnace lockout due to an excessive number of ignition retries (3). Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour.
Draft inducer is not operating or the pressure switch circuit has closed. Replace the induced draft blower pressure switch, or repair the short.
The pressure switch is open. Pressure switch may need to be replaced.
Pressure issue. High limit cut-off due to faulty wiring or bad filters. Replace or clean the air filter; clean drain tubes of moisture or debris; may have an open limit switch that requires a jump, ensure not to run it with the main switch bypassed.
The unit is sensing a flame without a call for heat. Might be the result of a slowly closing valve. Turn off the gas until the valve is fixed.
Faulty flame sensor. Flame sensor might be dirty or placed too far from flame. Clean if dirty, replace if defective.
Polarity of volt power is reversed. Review wiring diagram to correct polarity.
Freeze Protection Engaged. The room temperature measured by the wireless remote thermostat or indoor ambient thermistor active sensor falls below 40°F. No Action required. This setting will disengage when the room temperature rises above 43°F.
Front Desk switch is closed. All outputs are switched off. Open front desk switch to allow occupant unit operation.
Un-Configured Service Board – All operation held awaiting configuration. Enter Configuration Menu and set “C3” to “C” for coolers with electric heat or “H” for heat pumps.
Emergency Hydronic Engaged. The EHH switch is closed. Compressor is switched off. Open front emergency hydronic switch to allow occupant unit operation.
Load Shedding Engaged. The LS switch is closed. Compressor and Electric heat is switched off. Open load shedding switch to allow occupant unit operation.
Control is configured to respond to a wired thermostat. No action if a wired thermostat is being used.Otherwise, see Configuration Settings.
Open Door Lockout (DS1 & DS2 open; wireless). Close Room Door. Unit will not condition space with door open.
Window Switch Lockout – (LS & INN open). Close Room Door or Window. Unit will not condition space with door or window open.
Heat Sentinel – (WIAT > u3). No action required. This setting will disengage when the room temperature falls.
Un-Rented Status (EHH & INN or wireless). Front Desk needs to set to Rented mode (if applicable).
Indoor Ambient Thermistor reads outside the range -20°F to 200°F & the wireless thermostat is not communicating to the unit control or Indoor Ambient Thermistor (IAT) without a wireless remote thermostat reads outside the range -20°F to 200°F. Replace black Indoor Ambient Thermistor or Wireless Remote Thermostat.
Wireless Remote Thermostat failure. Replace Wireless Thermostat.
Indoor Ambient Thermistor reads outside the range -20°F to 200°F. Replace black Indoor Ambient Thermistor.
Indoor Coil Thermistor either above or below operating tolerances. Replace Red Indoor Coil Thermistor.
Wireless Thermostat failure. Attempt to rebind Wireless Thermostat or Replace Wireless Thermostat.
Indoor Discharge Thermistor either above or below operating tolerances. Replace Yellow Indoor Discharge Thermistor.
Low Remote Battery Warning. Replace Batteries in Wireless Devices.
High Voltage Protection engaged. Power supply voltage is to high. Check for incoming power at correct voltage.
Brown Out Protection engaged. Power was lost or voltage is low. Check for incoming power at correct voltage.
Discharge Air Too Hot. Clean Filter or Remove Air Blockage.
Outdoor Coil Thermistor temperature high. Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning.
Indoor Air Recirculation. Large delta between thermostat and return. Clean Filter or Remove Air Blockage or Close Vent Door or Improve indoor to outdoor seal.
Outdoor Coil temperature too high for outdoor ambient temperature. Check for Blocked Outdoor Air or Clean Coil.
Indoor Coil is freezing up. Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube.
Indoor Coil is freezing up. Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube.
Indoor Coil froze up. Clean filter, check for fan and blower operation, check for Refrigerant loss or restricted capillary tube.
Poor Unit Performance. Check for blower motor, compressor, or electric heat operation.
Indoor Freezing Lockout (ICT – IAT > 20) +10 Min. Clean filter, check for fan and blower operation, check for Refrigerant loss or restricted capillary tube.