ADP Unit Heater Repair
North Wind’s skilled technicians are adept at resolving any issues with ADP unit heaters, ensuring your comfort and warmth. Trust North Wind for expert assistance in repairing your ADP unit heater.



ADP HVAC Experts
At North Wind, our skilled technicians specialize in ADP unit heater repair services. We understand the importance of a properly functioning unit heater for maintaining comfort in your space, whether it’s a residential or commercial environment. Our team is equipped with the expertise and tools necessary to diagnose and fix any issues with ADP unit heaters promptly and efficiently. From minor adjustments to more complex repairs, you can rely on North Wind to restore your ADP unit heater to optimal performance, ensuring warmth and comfort when you need it most.
- Free Estimate
- Same-Day Service (24/7)
Are You Looking For
ADP Unit Heater Repair Near Me
When you’re in need of ADP unit heater repair nearby, look no further than North Wind. Our team of experienced technicians is committed to providing efficient and effective solutions to keep your heating system running smoothly. With our convenient location and prompt service, you can trust North Wind to quickly diagnose and address any issues with your ADP unit heater, restoring warmth and comfort to your home or business. Don’t let a malfunctioning heater disrupt your comfort – contact North Wind today for reliable ADP unit heater repair services just around the corner.
Expert Technicians
With Years of ExperienceFast and Reliable
Available 24/7Affordable Services
Quality Service, Unbeatable PriceCertified and Qualified
Fully Licensed, TSSA ApprovedNorth Wind HVAC
ADP Repair & Installation Services
What We Do:
ADP HVAC Services
ADP Unit Heaters Repair & Installation
When it comes to ADP unit heaters, North Wind is your go-to for reliable repair and installation services. Our experienced technicians are equipped to handle any issues with ADP unit heaters, from minor repairs to complete installations. We understand the importance of a properly functioning unit heater for maintaining comfort in your space, and we are committed to providing fast and efficient service to get your system up and running in no time. Trust North Wind for all your ADP unit heater needs.
How do I know if my ADP unit heater needs repair?
Common signs of a malfunctioning ADP unit heater include uneven heating, strange noises, reduced airflow, or a complete lack of heat. If you notice any of these issues, it’s advisable to seek professional repair services.
Can I repair my ADP unit heater myself?
While some minor maintenance tasks can be performed by homeowners, it’s recommended to leave complex repairs to qualified HVAC technicians. Attempting DIY repairs without proper knowledge and tools can lead to further damage or safety hazards.
What types of problems can occur with ADP unit heaters?
ADP unit heaters can experience various issues, including thermostat malfunctions, ignition problems, fan motor issues, gas valve failures, or clogged air filters. Professional technicians can diagnose and address these issues effectively.
How often should I schedule maintenance for my ADP unit heater?
It’s recommended to schedule annual maintenance for ADP unit heaters to ensure optimal performance and longevity. Regular maintenance can help prevent potential problems and keep your heater operating efficiently.
How long does it take to install an ADP unit heater?
The installation time for an ADP unit heater can vary depending on factors such as the complexity of the installation, the size of the unit, and any necessary modifications to existing ductwork or electrical systems. On average, installation can take a few hours to a full day.
ADP Air Handlers Repair & Installation
For ADP air handlers, North Wind offers top-notch repair and installation services to ensure your HVAC system operates at its best. Our technicians are trained to diagnose and repair any issues with ADP air handlers efficiently, restoring comfort to your home or business. Whether it’s a minor repair or a full installation, you can trust North Wind to deliver quality service and customer satisfaction.
ADP Evaporator Coils Repair & Installation
When it comes to ADP evaporator coils, North Wind’s repair and installation services ensure optimal performance and efficiency. Whether it’s a simple repair or a complete installation, our skilled technicians have the expertise to handle it with precision. We understand the importance of a properly functioning evaporator coil for your HVAC system, and our commitment is to provide prompt and reliable service to keep your system running smoothly.
We Are Here For You
Why You Should Contact Us
At North Wind, we prioritize customer satisfaction above all else. Our team of highly skilled technicians is dedicated to providing top-notch service, whether it’s repairing a malfunctioning ADP unit heater or installing a new HVAC system. We understand the importance of a comfortable and well-functioning indoor environment, which is why we go above and beyond to ensure our clients receive prompt and efficient service tailored to their specific needs. With years of experience in the industry, we have earned a reputation for reliability, professionalism, and attention to detail, making us the preferred choice for ADP unit heater repair and installation services.
Contact North Wind HVAC for exceptional service, and experience our dedication to your comfort.

ADP Unit Heaters Error Codes
2 flash (Exhaust blower runs constantly with 120 volts applied and no thermostat wires connected to the unit.)
The gas valve may be faulty and has to be replaced. Check the polarity and make sure the unit has a good ground. If setup for Propane, the inlet gas pressure switch my be open. Ensure inlet pressure is set per the rating plate. If pressure is good change the switch.
LED light not on (Nothing operates.)
Make sure 120 volts are present at the transformer (black & white) wires. If not, check the supply power. If there is, check for 24 volts across the (blue & yellow) wires. If 24 volts are not present, then the transformer is bad.
Steady slow flash (Nothing operates.)
Turn thermostat above room temperature. Thermostat wires should be connected to the “R” terminal and “W” terminal on the control board.
Steady fast flash (Nothing operates.)
If the exhaust blower does not come on, check for 120 volts at the CMB terminal on the control board. If 120 volts are present, replace the motor, if not replace the board.
Steady fast flash (Heater is short cycling. Runs for a few minutes then shuts off and does not lock out.)
Check to see if the pressure switch is opening during operation. If so, check pressure going to the pressure switch. If it drops down below the switch setting, inspect the tubing for cuts or nicks an clean out the barbed connecters on the exhaust blower. If pressure does not drop to switch setting and the pressure switch is opening, then the switch is bad.
2 flash (Unit locked out after three trials. Sparks but will not light.)
Ensure the gas valve is in the on position. Check the spark igniter gap. It should be 1/8″. Some LP models have an inlet gas pressure switch mounted on the gas valve. Refer to the installation manual and make sure the gas supply pressure meets the minimum requirements. If it does, purge air out of the gas supply line. Are 24 volts present at the valve? If not, replace the board. If 24 volts are present and the valve will not open, then the transformer may be to weak to handle the load.
2 flash (Will light, but will not stay lit. Unit goes into lock out. )
Gas pressure must be set according to the rating plate. Heater must have a good ground for proper ignition and flame sensor operation. Check to see if the flame sensor is cracked or grounded. Check the sensor wire for continuity. Ensure proper flame current signal from the flame sensor. Flame signal should be at least .6 micro amps.
4 flash (Unit fires up, but the fan motor will not come on, causing the limit to open.)
There should be 120 volts at the ACC terminal on the control board, if not the board is bad. If there is, then the fan motor is bad. Fan motor neutral wire not connected to the supply voltage neutral.
4 flash (Upper rollout limit keeps tripping.)
Ensure the manifold pressure is set per the installation manual. If manifold pressure is correct, replace switch with part number 65361900. Visually check for proper flame at heat exchanger inlet.
3 flash (Exhaust blower comes on but nothing else happens.)
Make sure the tubing is connected to the pressure switch and the exhaust blower. If it is, inspect it for cuts or nicks. If the tubing looks good, replace the pressure switch.
3 flash (When the heater receives a call for heat, it goes into a lock out.)
If the pressure switch is closed before the exhaust blower comes on, replace the pressure
switch.
4 flash (Installed a control board conversion kit, and the fans run constantly.)
Unit was wired incorrectly. Refer back to the kit instructions. Limit circuit and pressure switch circuit may be cross wired.
Please note that these error codes are general and may not cover every possible variation. Always refer to your ADP unit heater manual or consult a professional technician for accurate diagnosis and resolution.
Quality Brands We Trust
Brands We Service

Every HVAC Repair and Installation Service Under One Roof!
Get in touch with our experts to book your appointment, today.
Quick Response within 2 Hours
Same/ Next Day Service
Best Prices
Top Rated
24/7 Support, Repair & Installation